Enterasys 6000 User Guide

Page of 420
Configuring BSC
9-17
Subscriber Parameters
1 The software does not  verify that the specified LP/port  exists.  Make sure  the specified 
LPs and ports are  configured in the database,  and that  they actually exist.
Subscriber Name
identifies the subscriber to the console operator. The FRX/FRM software does not use 
this information.
Routing Algorithm
allows creation of a "hunt group" of ports (see example in Appendix B), for the 
purpose of routing per a pre-selected algorithm:
0
 = Round Robin – selects ports specified cyclicly in numerical order according 
to the list of Redirection Addresses. If the selected port is unreachable or con-
gested, the Call Request will be sent to the next port. (If the port becomes 
available again, it will be included in its assigned position.)
1
 = Alternate Route on Line Failure – selects the first port that is not in a failed 
state. If the selected port does not make a connection, the call will be cleared, even 
if other ports are available.
2
 = Alternate Route on Line Busy – selects the first port that has LCNs available 
(is not busy). If the port has failed, the next available port will be selected.
3
 = Least LCN with Throughput – selects the line with the minumum loading, cal-
culated by  weight and number of LCNs  in  use  on that line.  (Each  line  is assigned 
a weight proportional to its throughput within the routing path.)
If  use of a routing algorithm is not  desired, simply  accept the default, and specify only 
one routing path.
Table 9-3    SVC Subscriber Parameters
Parameter
Valid Values
Default Value
Subscriber Name
0–31 characters
none
Routing Algorithm
0–3
0
Systematic Redirection
Y/ N
N
Redirect on  Busy
Y/ N
N
Redirect on Out of O rder
Y/ N
N
Connecti on Priori ty
0–9
0
1st,2nd,etc.  Path Configured
Y/ N
N
LP
FRX4000, FRM:
 0 
1
FRX6000: 
0–7 
1
0
Por t
Physical port:
 
0–7 
1
Logical port: 
8–63
 
1
0
Redirection  Address 0, 1,etc.
valid address
none