Enterasys 6000 User Guide

Page of 420
16-2
FRX/FRM 3. 3 User G uide, Rev 04
On-Line Node Operations
Remote Control
Remote control allows an operator to control a remote FRX/FRM via:
a connection through a network  into a physical or logical (via frame  relay) X.25 
port on the node to be controlled, or
an async terminal connected to an async PAD port, through a network, into an 
X.25 port on the node to be controlled.
These restrictions apply to the Remote Control operation:
An FRX/FRM cannot be controlled by more than one device at a time.
While remotely controlling one node, you cannot take remote control of another 
one.
While a node is under remote control, its keyboard is blocked to prevent local 
operation.
Subscriber ID
 record for the controlled node must be configured in the node that will 
be at the controlling end. The 
Subscriber ID
 in this record must be the 
Remote Control 
ID
 in the 
Node Defaults
 record of the node to be controlled. The 
1st Routing Path
 in the 
Subscriber record must be the local port in the controlling node through which the 
remote connection will be made.
Remote Control from Another FRX/FRM
1. Press 
[A]
 at the On-Line Node Operations Menu
 
(or
 [B], [A], [A]
 from the
 
Main 
Menu) of the controlling node. When prompted, enter a 
Remote Control  ID
 and 
Remote Control ID Password
, configured in Node Defaults (
[A], [A] 
from the Main 
Menu, or see Chapter 3) on the node you want to control.
2. When prompted to press any key to continue, press 
[Enter]
.
3. The remote ID  (
Node Name
) is displayed as 
wait 
during Call Request processing. 
If a Call Accept is not received in the time specified by the X.25 parameter 
Incoming Call Timeout
, the remote ID is displayed as the
 Node Name
 configured 
in 
Node Defaults
 on the local node. Once the connection is successful, the dis-
played remote ID becomes the 
Remote Control  ID
 specified  for the  controlled 
node.
4. When asked: 
Are you  a PAD  user?
, type 
n [Enter]
.
5. When prompted, enter the password of the controlled node. The display at the 
controlled node will say:
 Under remote control. Keyboard blocked by  id = "n."
 The 
Main Menu at the controlling node will act as the Main Menu of the controlled 
node, and the displayed remote ID is the ID of the controlled node.