Enterasys 6000 User Guide

Page of 420
Appendix E
NetView Management
The Netlink FRX4000, FRX6000, and Frame Relay Module support a NetView 
service point function, which allows a node to be configured and managed from a 
NetView host. NetView support provides management access to downstream SDLC 
devices, and allows diagnosing problems and changing parameters in the node.
The service point in the FRX/FRM connects to the NetView host via an LLC2 session 
(over LAN or frame relay), which is established at node IPL. LLC2 must be installed 
in either the service point node or another FRX/FRM that is connected to the service 
point node via X.25 (physical link or over frame relay per Annex G or RFC 1490). 
(The link can be between two nodes of any type among FRX4000, FRX6000, and 
FRM.)
The NetView host (also referred to as a focal point) sends commands to the service 
point in the form of NMVTs (network management vector transports). The service 
point function translates information from the node into NMVTs and responds to the 
host. Four types of NMVTs can be transmitted:
RUNCMDs – commands from the host to execute specified operations. Three 
types of command are supported:
Display – used to display status and configuration information
Vary – used to change the active/inactive status of a PU or line.
Modify – used  to change configuration of a PU and  the line between it  and 
the node.
RUNCMD replies – from the service point to the host.
Alerts – unsolicited information about events in the node, lines, or PUs.
LPDAs – link problem determination aids, which are procedures used to test 
status and to control the node, communications line, and PU interface.
FRX4000, FRX6000, and FRM support LPDA versions 1 and 2.
The actual command syntax used in NMVTs from the host is documented in IBM’s 
VTAM Operation manual. Responses to host commands generally use the textual 
characteristics of VTAM (with a different prefix).