Warning Messages
These messages may be displayed on some screens if there is a problem with the con-
figuration for alarm reporting.
Primary Alarm Reporting Error
will appear at the top of all screens on a collecting node if the software that drives the 
alarm output device is unable to output to the device.
Primary  NOT Configured
will be displayed at the bottom of both Node Defaults screens if a 
Primary Alarm 
Output ID
 is not specified.
Primary/Secondary C/P"n"  NOT installed
will be displayed at the bottom of both Node Defaults screens if a serial (
C
) or parallel 
(
P
) port is specified for the 
Primary/Secondary Alarm Output ID
, but  the card containing 
the port is either incorrectly configured or is not installed. For a serial port, this 
message will also be displayed if the card is properly installed but the device at the 
other end is not.
Primary/Secondary Printer/Connection  Problem
will be displayed at the bottom of both screens if a parallel (
P
)  port is specified and the 
card containing the port is installed but the device at the other end is not. Note that this 
will not be determined by the software until the first alarm is sent to the parallel port.
 Primary/Secondary  C/P"n" NOT  Initialized
will be displayed at the bottom of all both screens if a serial or parallel port is spec-
ified, but either the software cannot find the specified port or it is in use for some other 
purpose.
Errmsg.txt Database  Error
will be displayed if the file ERRMSG.TXT can not be found on the disk. (This may 
happen if a software update was not correctly installed.) To correct this on an 
FRX4000, the file can be transferred from a remote FRX/FRM or copied from a 
locally attached PC (with Procomm), as described on page 16-8. On an FRX6000, the 
file can be created with the following procedure:
1. Press 
[F10]
 at the Main Menu.
2. When asked: 
Reboot the Netlink  FRX6000?
, press 
[Y]
.
3. As the node starts to boot, press
 [Ctrl] [C]
.
4. When asked: 
Terminate batch  job?
, press 
[Y]
.
5. At the DOS prompt, type 
generr.exe [Enter]
.
6. To restart the FRX6000, type 
omni4 [Enter]
.