Configuring Serial Port s
5-5
Configuring a Physical Port
Before configuring a physical port, make sure that the following have been properly 
configured:
Node parameters. See Chapter 3. This is general configuration that must be done 
no matter which protocols will be run in the node.
Line Processor that contains the port, plus  Line Interface  Card that supports the 
port. See Chapter 4.
Protocol(s) that will be transmitted over the physical port and any logical ports 
on the physical port. See Chapter 4.
Once these necessary records have been configured, press 
[A]
 (
Configuration
), then 
[C]
 
(
Configure Ports
), then 
[A] 
from the Main Menu. As prompted, enter:
LP number of the RLP containing the port: 
0–7
 for FRX6000, 
0
 only for 
FRX4000 or FRM. (The default is 
0
.) (LP numbers  are  described in Chapter  4.)
Port number (see Figure 5-1 through Figure 5-3)
0–7
. (The default is 
0
.)
The display for an existing record will show the configured parameter values, while 
the display for a new record will show values stored in a default database record. The 
following figure is an example of a new record.
Figure 5-4    Default Configuration Screen for New Port
[A],[C],[A]
 from  Main Menu
R mtid =n odexyz
X .25  Port Parameters (s creen  1  of 6)
*
RLP: 0
Port: 5
Link State:
Link_d is able
*
I/O: V .35
Datab ase
Sys tem Memory
A Port Typ e
X.25
X.25
B Ph ysical Port I nterface
V.35
V.35
C Blocked Port Flag
N
N
D Lin e  Speed
9600 b ps
9600 b ps
E Mod ulo
8
8
F Maximum  LAPB Wind ow S ize
7
7
G N2 R etrans mit Cou nt
5
5
H T1 Retransmit  Period  (msec)
2000
2000
I
T2 Wait A ck  Period  (msec)
1000
1000
J
T3 Link  Alive  Period  (s ec)
10
10
K Logical DC E
N
N
L Generate Clock
N
N
M Rcv Clock  (TT) from D TE
N
N
O On -Lin e System Memory Ch anges
N
Option: