Qsc sra 1222 User Manual

Page of 40
13
SETUP- 
AC Power Requirements
AC Power
Verify operating voltage before plugging
amplifier into AC mains. Make sure the AC
mains voltage is the same as specified on the
serial number plate.
Do not use a smaller gauge cord than supplied
with the amplifier! 120 Volt models are sup-
plied with a #14 AWG cordset. 220 Volt models
are supplied with 1.0 mm
2
 cordset.
Do not use improper AC mains
voltage! It can create hazardous
conditions and severely damage
the amplifier!
AC Power Connection
120 Volt Models, 15 Amp Receptacle.
Insert the plug fully.
240 Volt Models, European  three
conductor Earthing Receptacle
Insert the plug fully.
The serial number plate is affixed to the rear panel,
bottom right corner, adjacent the AC cord entry.
Plug the IEC-style end of the cord into the amplifier. Plug the AC mains-end of
the cord into the AC outlet.
IEC Inlet
(amplifier end of cord)
Orient the IEC-style connector
correctly with the inlet, then
insert the plug fully.
Typical AC Line Current Consumption
5.6 amps
at 4 ohms
5.0 amps
at 8 ohms
8.0 amps
at 8 ohms
Conditions: 120 VAC line, both channels
driven with pink noise at 1/8 rated power.