Hoshizaki FH1-SSB(-HD) User Guide

Page of 23
1
Alarm Signals
Alarm Code
Alarm 
Sound
Problem
Reset Options
E4
6 beeps 
every ten 
seconds
High Pressure Alarm 
 
Compressor discharge pressure is 
outside of the normal operating range. 
The high pressure switch has been 
triggered 3 or more times in 1 hour. The 
air filter and/or condenser may need 
cleaning. 
Clean the air filter and/or condenser if 
necessary. Press "RESET." If the high 
pressure switch resets automatically, the 
alarm will be silenced and "E4" will clear.  
 
If the high pressure switch trips 5 times 
in 1 hour, the compressor will stop and 
will not re-start. A service technician must 
be called. After the 5th pressure trip, 
the alarm can be silenced for 1 hour by 
pressing "RESET."
E6
8 beeps 
every ten 
seconds
High Voltage Alarm 
 
Line voltage has been too high for 
at least 10 seconds. To protect the 
compressor, the compressor has shut 
down.
The alarm automatically resets when 
acceptable voltage is detected. 
 
Press "RESET" to silence the alarm for 
5 minutes. If this alarm occurs frequently, 
call a qualified service technician.
E7
9 beeps 
every ten 
seconds
Low Voltage Alarm 
 
Line voltage has been too low for at least 
10 seconds. To protect the compressor, 
the compressor has shut down.
The alarm automatically resets when 
acceptable voltage is detected. 
 
Press "RESET" to silence the alarm for 
5 minutes. If this alarm occurs frequently, 
call a qualified service technician.
E8
Constant 
buzzer
Cabinet Temperature Sensor Malfunction 
Alarm 
 
Cabinet temperature sensor has failed.
Call a qualified service technician.  
 
During alarm, press "RESET" to silence 
the buzzer for 5 minutes. 
E9
Constant 
buzzer
Defrost Temperature Sensor Malfunction 
Alarm 
 
Defrost temperature sensor has failed.
Call a qualified service technician.  
 
During alarm, press "RESET" to silence 
the buzzer for 5 minutes.
CF
1 beep 
every ten 
seconds
Clogged Filter Alarm 
Condenser temperature is outside of 
normal operating range. 
Air filter and/or condenser require 
cleaning.
Clean the air filter and/or condenser. 
Allow time for the sensor to reset, then 
press "RESET." 
 
During alarm, press "RESET" to silence 
the alarm for  hours. 
 
If this alarm occurs frequently, call a 
qualified service technician. Failure 
to take action when this alarm 
activates could result in damage to the 
compressor. 
door 
(except 
units with 
heated 
glass doors)
 beeps 
every ten 
seconds
Door Alarm 
 
Display Only: Door open. 
Both Display and Beeps: Door open 
longer than 3 minutes.
Close the door. During alarm, press 
"RESET" to silence the buzzer for 
3 minutes.
2. SafeTemp Models
There are no alarms on SafeTemp models.