6. RS-232 & RS-485 Protocol 
 
6.1 Setup 
 
6.1.1 Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 exchanged, see pin 
configuration chart below for details) to connect the COM 1 on the rear panel of the DVR to a PC. 
 
 
 
 
6.1.2 Set the RS-232 option to ON in the COMMUNICATION page of the setup menu. 
 
6.1.3 Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit. 
 
 
 
6.2 Communication Protocol 
 
 
 
6.2.0 General Command Format 
<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, {<Number of 
parameters>,<Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f> 
 
 
 
 
 
     Lead Code  = 0x41 
Dest ID     = 0x01 
Src ID     = 0x20 
 
 
     Main Category  = 0x01   Keys and Signals 
 
 
           
   
= 0x02   Command 
                              Second Category    = 0x01 Handshake 
 
 
 
                             
= 0x02 Request Time/Set Time 
     
 
 
 
 
  = 
0x06 
Request 
System 
State 
 
 
     End Code= 0x4f