Lexmark X850e Reference Guide

Page of 120
91
2
Understanding MFP messages
Messages appear on the MFP control panel describing the current state of the MFP and indicating possible MFP problems 
requiring intervention.
Status messages
Status messages provide information on the status of the MFP.
Message
Meaning
Action
Bin [x] Full
x represents the number of the 
output bin that is full when the MFP 
bins are linked.
Remove print media from the bins. The message 
clears once the output level of the linked bins is no 
longer full.
Busy
The MFP is busy receiving, 
processing, or printing data.
Press Stop to access the job queue.
Flushing Buffer
The MFP flushes corrupted data and 
discards the current print job.
Hex Trace
The MFP is in Hex Trace mode.
Hex Trace isolates the source of a 
print job problem. When Hex Trace is 
active, all data sent to the MFP prints 
in hexadecimal and character 
representation.
Exit Hex Trace to print jobs normally. To exit Hex 
Trace, unplug the MFP.
[linked set bin 
name] Full
The linked set of bins with a 
previously defined name is full.
Remove print media from the bins. The message 
clears once the output level of the linked bins is no 
longer full.
Maintenance
The MFP maintenance counter has 
exceeded its limit, so the MFP 
requires maintenance.
Replace the maintenance items. If necessary, reset 
the MFP maintenance counter.
Network
Network [x]
Network [x], [y]
A network interface is the active 
communication link.
Wait for the message to clear.
Notes:
• The current interface appears on the Menu Settings 
Page. Interfaces shown without an x or y means the 
active host interface is a standard interface.
• x indicates the active interface is connected to the 
MFP through PCI connector x.
• x, y indicates the active interface is connected to 
the MFP through channel y on PCI connector x, or 
that x equals 0 on the standard network interface.
Parallel
Parallel [x]
A parallel interface is the active 
communication link.
Serial [x]
A serial interface is the active 
communication link.
USB
USB [x]
The MFP is processing data through 
the specified USB port. 
PC Unit Life Warning
The photoconductor unit is nearly 
empty or near the end of its usable 
life.
Note: The Menu Settings Page 
shows a gauge to indicate the 
remaining current life.
• The message is cleared automatically when the 
cover or door over the photoconductor unit is 
opened or if the MFP power is turned off and then 
on.
• Replace the photoconductor unit. If it is not 
replaced, the MFP issues the message again when 
the door or cover is closed.