Specifications
Environment
Operating
Temperature
Dry Bulb:
50°F to 104°F (10°C to 40°C)
Humidity:
10 to 90% noncondensing with a maximum wet bulb
temperature of 82°F (28°C) and a minimum dew point of
36°F (2°C )
Altitude:
To 8,000 ft. (2438 meters)
Nonoperating
Temperature:
Boxed:
-40°F to 151°F (-40°C to 66°C)
Unboxed:
14°F to 122°F (-10°C to 50°C)
Humidity:
10 to 95% noncondensing
Altitude:
To 10,000 ft. (3048 meters)
Thermal Shock:
61°F (20°C) per hour
Vibration:
Units meet NSTA (National Safe Transit Association)
 requirements.
Heat Load Contribution
The average heat load contribution to the environment is approximately 735
BTUs per hour (215 Watts).  The minimum heat load contribution is approxi-
mately 100 BTUs per hour (30 watts).  The maximum is 2050 BTUs per hour
(600 Watts), under continuous full-load printing conditions.
Table S–3.  Heat Load Contributions
Printing Conditions (110 VAC/60 Hz)
Wattage
BTU/Hr
Power On, not printing
55 W
188
100% Uppercase Rolling ASCII
400W
1370
Black Page Plot
600 W