GE dncd450eawc Specification Guide

Page of 3
DNCD450EA/GA – GE Super 7.0 Cu. Ft. Capacity Commercial Dryer
Specification Revised 2/03
GE Appliances
Dryer Dimensions (in inches)
Exhaust Options:
Electric: 
4-way via rear, right, left and bottom. Maximum recommended exhaust
duct length is 45 feet of 4" rigid ducting with two 90° elbows and a 4" dampered
wall cap.
Gas: When viewed from the front of the unit, exhaust 3-way via rear, left and
bottom. Maximum recommended exhaust duct length is 15 feet of 4" rigid 
ducting with two 90° elbows and a 4" dampered wall cap.
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a 30-amp circuit
breaker or a time-delay fuse, is required.
Electric Dryer Rating: 
208/240V, 5600W, 24A, 60Hz
208V, 4400W, 22A, 60Hz
Note: Dryer wall outlet must be located within 36" of service cord entry and
accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions
packed with your dryer.
36
42
27
2
3-1/2
2-1/2
25-1/2*
Side View
Rear View
8-1/2
28-1/4
23-1/2
11-1/2
*24-1/2" from the edge of the side panel to the front.
 25-1/2" from front to edge of endcaps.
For answers to your Monogram,
®
GE Profile
or 
GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center
®
service, 800.626.2000.
R
Listed by
Underwriters
Laboratories