GE CGS980SEMSS Specification Guide

Page of 2
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
Specification Revised 6/08
230151
Electrical Requirements: 120v; 60Hz, 15A
Effective January 1, 1996, the National Electrical Code 
requires that new construction (not existing) utilize a 4-
conductor connection to an electric range.
Receptacle Locations: Locally approved flexible service 
cord or conduit must be used because terminals are 
not accessible after range installation. See shaded 
area in drawing for location of electrical outlet box. 
Recommended outlet locations allow range to be installed 
directly against wall.
Note: 30" ranges conform to U.L. requirements for 0" 
spacing from adjacent walls below countertops. To reduce 
possibility of scorching walls, engineering recommends a 
minimum of  
1-1/2" spacing to allow for possible extended, high-heat, 
no-load heating element operation.
Installation information: Before installing, consult 
installation instructions packed with product for current 
dimensional data.
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation  
of the range.
Dimensions and Installation Information (in inches) 
CGS980SEMSS 
GE Café
 
30" Free-Standing Gas Range
 
30"
37-1/4"*
26-1/2"
46-3/4"
36-1/4"
+_
1/4
9
30
2
4 4
24
13
14-1/2
2-1/2
Recommended area 
for thru the floor 
connection of pipe stub 
and shut-off valve
Recommended common 
area for gas outlet and 
electrical outlet
Recommended 
area for 120V outlet 
on rear wall and 
area for thru the 
wall connection 
of pipe stub and 
shut-off valve
*41-1/4" with optional backguard kit
30"
37-1/4"*
26-1/2"
46-3/4"
36-1/4"
+_
1/4
9
30
2
4 4
24
13
14-1/2
2-1/2
Recommended area 
for thru the floor 
connection of pipe stub 
and shut-off valve
Recommended common 
area for gas outlet and 
electrical outlet
Recommended 
area for 120V outlet 
on rear wall and 
area for thru the 
wall connection 
of pipe stub and 
shut-off valve
*41-1/4" with optional backguard kit