GE phs925stss Specification Guide

Page of 2
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
PHS925STSS 
GE Profile
™ 
Slide-In Induction Range
 
Specification Revised 11/11
220456
Listed by 
Underwriters 
Laboratories
Dimensions and Installation Information (in inches) 
Note: To reduce the possibility of scorching the side walls above the countertop 
when no load is present on burners, it is recommended that a minimum 6" 
spacing from adjacent side wall be allowed for possible extended high-heat 
element operation.
Receptacle Locations: For all 30" Slide-In Ranges locally approved flexible 
service cord or conduit must be used because terminals are not accessible 
after range installation. See shaded area in drawing for location of electrical 
outlet box. Recommended outlet locations allow range to be installed directly 
against rear wall. 
KW Rating
240V 12.2
208V 9.2
Breaker Size
240V 40 Amps
208V 40 Amps
Installation information: Before installing, consult installation instructions 
packed with product for current dimensional data. 
Note: Use a 4’ power cord to prevent interference with the storage drawer. Power cords 
4-1/2’ to 6’ long may have to be dressed to allow for proper drawer closing.
Minimum dimensions between cooktop, walls and above the cooktop: 
A. Make sure the wall covering, countertop, flooring and cabinets around the range can 
withstand the heat (up to 200°F) generated by the range. 
B. Allow 30" minimum clearance between surface units and bottom of unprotected wood or 
metal cabinet, or allow a 24" minimum when bottom of wood or metal cabinet is protected by 
no less than 1/4" thick flame retardant millboard covered with not less than No 28 MSG sheet 
metal, (.015"), .015" thick stainless steel, .024" aluminum or .020" copper. Acceptable electrical 
outlet area. Orient electrical receptacle so the length is parallel to floor.
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. 
However, a 6" minimum spacing to surfaces less than 15" above the cooktop and adjacent 
cabinet is recommended to reduce exposure to steam, grease splatter and heat. To reduce 
the risk of burns or fire when reaching over hot surface elements, cabinet storage space 
above the cooktop should be avoided. If cabinet storage space is to be provided above the 
cooktop, the risk can be reduced by installing a range hood that projects at least 5" beyond 
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13".
Note: Use a 4'power cord to prevent 
interference with unit when installing. 
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation  
of the range.