Bosch 1006vsr 3 User Manual

Page of 12
 
 
 
Figure 4 
6.  Plug the planishing hammer into the power 
supply. 
7.  With the workpiece between the hammer 
and anvil (Figure 5), press the foot switch to 
begin planishing. 
Note: Planishing blows-per-minute can be adjusted 
by turning adjustment knob (see Figure 2). 
 
Figure 5 
Changing Dies 
Referring to Figure 6: 
The PH-24T is shipped with one crowned anvil 
(or lower) die, and one flat hammer (or upper) 
die, which is already installed in the driver.  
To remove an anvil die, loosen the set screw 
and pull straight up on the anvil die. Install a new 
anvil die and tighten set screw. The anvil post 
accepts dies with a standard 0.79” insert end. 
To remove a hammer die from the driver, use a 
tool to separate them. When the die is removed, 
check the condition of the o-ring inside the 
driver. To reinstall a hammer die, insert it into 
the driver and raise the anvil post up until it 
contacts and pushes the die in. 
  
To remove the entire driver from the hammer 
barrel, push the tab on the air hammer housing 
and pull down on the driver. To reinstall the 
hammer drive, orient the notch toward the 
general direction of the tab, and push driver 
upward while still pushing back on the tab. 
When the driver is properly inserted, the tab will 
snap back into place.  
 Make sure driver and dies are 
properly inserted before operating machine. 
 
Figure 6 
Maintenance 
Check the following before every use: 
ˆ  Oil level in the lubricator; refill as needed 
with ISO 32/SAE 10W non-detergent, non-
additive oil. Remove oil plug with a 
screwdriver to fill. 
ˆ  All mounting and component hardware and 
fasteners; adjust/tighten as necessary. 
ˆ All air connections; replace leaking or 
defective connections. 
ˆ Worn or shorted wiring; replace as 
necessary. 
Periodically check the filter/regulator bowl for 
fluids or sediment accumulation, and empty it if 
needed. To remove a bowl, shut off air supply 
and bleed excess air; then press the tab, rotate 
bowl to the left, and pull down. Reverse 
procedure to reinstall bowl. Make sure bowl is 
locked in position before applying air to the 
system!