Alcatel-Lucent 6850-48 Network Guide

Page of 1162
Switch Logging Commands Overview
Using Switch Logging
page 46-10
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
Disabling an IP Address from Receiving Switch Logging Output
To disable all configured output IP addresses from receiving switch logging output, enter the following 
command:
-> no swlog output socket
No confirmation message will appear on the screen.
To disable a specific configured output IP address from receiving switch logging output, use the same 
command as above but specify an IPv4 or IPv6 address. For example:
-> no swlog output socket 174.16.5.1
Displaying Switch Logging Status
You can display the current status of switch logging on your console screen by using th
command. The following information is displayed:
• The enable/disable status of switch logging.
• A list of current output devices configured for switch logging.
• The switch logging severity level for each application that is not set to the “info” (6) setting.
The following is a sample display:
-> show swlog
Switch Logging is:
- INITIALIZED
- RUNNING
Log Device(s)
----------------
flash
console
Only Applications not at the level ‘info’ (6) are shown
Application ID
Level
----------------------------
CHASSIS (64)
debug3 (9)
->
For this example, switch logging is enabled. Switch logging information is being sent to the switch’s flash 
memory and to the console. Additionally, the severity level for the chassis application ID has been set to 
the “debug3” (or “9”) severity level.