Alcatel-Lucent 6850-48 Network Guide

Page of 1162
Configuring Ethernet Ports
Non-Combo Port Defaults
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
page 1-3
Non-Combo Port Defaults
The following table shows non-combo port default values: 
Combo Ethernet Port Defaults
The following table shows combo Ethernet port default values for OmniSwitch 6400 Series, OmniSwitch 
6850 Series, and OmniSwitch 6855 Series switches only: 
Parameter Description
Command
Default Value/Comments
Interface Line Speed
Auto (copper ports)
100 Mbps (fiber ports)
1 Gbps (GNI ports)
10 Gbps (XNI ports)
Duplex Mode
Auto (copper ports)/Full (fiber, 
GNI and XNI ports)
Autonegotiation
Enable for all copper ports;
Disable for all fiber ports
Crossover
Auto for all copper ports; 
MDI for all fiber ports (not config-
urable on fiber ports)
Flow Control (pause)
Disabled
Parameter Description
Command
Default Value/Comments
Preferred fiber
Forced fiber
Preferred copper
Forced copper
Preferred fiber
Interface Line Speed
Auto
Duplex Mode
Auto 
Autonegotiation
Enable
Crossover
Auto for all copper ports
Flow Control (pause)