Alcatel-Lucent 6850-48 Network Guide

Page of 1162
Configuring BFD
BFD Defaults
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
page 30-3
BFD Defaults
The following table shows the default settings of the configurable BFD parameters.
Parameter Description
Command
Default Value/Comments
BFD global status for the switch
Disabled 
Global transmit time interval for BFD 
control packets
100 milliseconds
Global receive time interval for BFD 
control packets.
100 milliseconds
Global operational mode and echo 
status 
Asynchronous mode with the 
echo function enabled
Global BFD echo packet time interval
100 milliseconds
Global Layer 2 hold-down (conver-
gence) timer value.
500 milliseconds
Administrative status of a BFD inter-
face
Disabled 
Transmit time interval for a BFD 
interface.
100 milliseconds
Receive time interval for the BFD 
interface.
100 milliseconds
BFD interface dead interval multi-
plier.
3
Echo time interval for the BFD inter-
face
100 milliseconds
Operational mode and echo status for 
the BFD interface.
Asynchronous mode with 
the echo function enabled.
Layer 2 hold-down (convergence) 
timer value for the BFD interface
500 milliseconds
BFD status for the OSPF protocol 
Disabled
BFD status for an OSPF interface 
Disabled
BFD session status with all neighbors 
of the corresponding interface which 
are greater than or equal to “2-way” 
state
Enabled 
BFD status for the BGP protocol
Disabled
BFD status for BGP neighbors 
Disabled
BFD status for VRRP protocol
Disabled
BFD status for a VRRP tracking pol-
icy. 
Enabled 
BFD status for a static route.
Disabled