Alcatel-Lucent 6850-48 Reference Guide
Ethernet OAM Commands
OmniSwitch CLI Reference Guide
September 2009
page 28-33
ethoam fault-reset-time
Configures the timer value for the Fault Notification Generation Reset time that specifies the time inter-
val, during which the fault alarm is re-enabled to process faults. The fault alarm will only be re-enabled if
no new faults are received during this time interval.
val, during which the fault alarm is re-enabled to process faults. The fault alarm will only be re-enabled if
no new faults are received during this time interval.
ethoam fault-reset-time centiseconds endpoint endpoint_id domain {mac_address | domain_name}
association association_name
association association_name
no ethoam fault-reset-time endpoint endpoint_id domain {mac_address | domain_name} association
association_name
association_name
Syntax Definitions
centiseconds
The Fault Notification Generation Reset timer value, in centi seconds.
The valid range is 250–1000.
The valid range is 250–1000.
endpoint_id
Specifies the MEP of a specific MA. The valid range is 1–8191.
mac_address
Specifies the CFM system MAC address.
domain_name
Specifies the domain name. For more information on the different
formats of the domain name, refer to
formats of the domain name, refer to
association_name
Name of the Ethernet OAM Association. Up to 48 (minus the domain
name length) characters may be used.
name length) characters may be used.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• Use the no form of this command to to restore the Fault Notification Generation Reset timeout value to
its default value.
• The Fault Notification Generation Reset timer value is configurable per MEP.
Examples
-> ethoam fault-reset-time 10 end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
-> no ethoam fault-reset-time end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
parameter
default
centiseconds
1000