A switch unit can be mounted in a standard 19-inch equipment rack or on a desktop 
or shelf. Mounting instructions for each type of site follow.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following factors:
•  Temperature: Since the temperature within a rack assembly may be higher than 
the ambient room temperature, check that the rack-environment temperature is 
within the specified operating temperature range. (See  page C-34.)
•  Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.
•  Circuit Overloading: Be sure that the supply circuit to the rack assembly is not 
overloaded.
•  Grounding: Rack-mounted equipment should be properly grounded. Particular 
attention should be given to supply connections other than direct connections to 
the mains. 
To rack-mount devices:
1.
Attach the brackets to the device using the screws provided in the Bracket 
Mounting Kit.
Figure 2-2.  Attaching the Brackets