Rotel RCC-1055 Supplementary Manual
RCC 1055
RS232 Controller Command List
Table: RCC 1055 Waveform format expected:
• For units BEFORE serial # 077-7121001 (Black) or 977-7121001 (Silver):
Baud Rate
Parity
Valid Data Bits
Stop Bit Value
Handshaking
Data Type
2400 N
8
1
None
String
• For units AFTER serial # 077-7121001 (Black) or 977-7121001 (Silver):
Baud Rate
Parity
Valid Data Bits
Stop Bit Value
Handshaking
Data Type
9600 N
8
1
None
String
Table: RCC 1055 expected format of a request by RS 232 controller:
Start Count Device
ID Type Key Checksum
0xFE 0x03 0xB0 0x10
0xXX 0xXX
Table 1: Type 10 Primary Command List
NOTE: The values in the table below show the exact byte sequence of all requests. The device
will expect the bytes only - no spaces, no delimiter, etc. The controlling device may implement its
own method to download each command sequence. The numerical values in the first column are
Hexadecimal.
RCC 1055 HEX
Command
Command Description
FE 03 B0 10 00 C3
Random Random
FE 03 B0 10 01 C4
Repeat Repeat
FE 03 B0 10 02 C5
Time Time
FE 03 B0 10 03 C6
Program Program
FE 03 B0 10 04 C7
Scan Scan
FE 03 B0 10 07 CA
Review Review
FE 03 B0 10 09 CC
1 1
FE 03 B0 10 1D E0
2 2
FE 03 B0 10 1F E2
3 3
FE 03 B0 10 0D D0
4 4
FE 03 B0 10 19 DC
5 5
FE 03 B0 10 1B DE
6 6
FE 03 B0 10 11 D4
7 7
FE 03 B0 10 15 D8
8 8
FE 03 B0 10 17 DA
9 9
FE 03 B0 10 12 D5
10 10
FE 03 B0 10 16 D9
+10 +10
FE 03 B0 10 0A CD
Search <<
Search <<
FE 03 B0 10 0B CE
Pause Pause
FE 03 B0 10 0E D1
Track |<<
Track |<<
FE 03 B0 10 0F D2
Stop Stop
FE 03 B0 10 10 D3
Open / Close
Open / Close
FE 03 B0 10 13 D6
Play Play
FE 03 B0 10 1A DD
Track >>|
Track >>|
FE 03 B0 10 1E E1
Search >>
Search >>