Installation
INSTALLATION
• Pick a location which will allow the conditioned air
to blow into the area you want. Good installation
with special attention to the proper position of the
unit will lessen the chance that service will be
needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard
unused parts
HOW TO INSTALL
Identify the existing wall sleeve before
installing the unit from the listed below.
All wall sleeves used to mount the new
Air Conditioner must be in sound structural
condition and have a rear grille that securely
attaches to sleeve, or rear flange that serves as a
stop for the Air Conditioner,
Remove old air conditioner from existing wall
sleeve.
Clean the interior of an existing sleeve.
(Do not disturb seals.)
Wall sleeve must be securely fastened in wall
before installing the air conditioner. Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
Prepare the wall sleeve for installation of the
unit. If you plan to use your existing wall
sleeve, and it is not LGE, use procedure B or
C below.
Install new unit into wall sleeve.
CAUTION:
When installation is
completed, replacement unit MUST have a
rearward slope as shown.
Tips
1
2
3
4
5
6
1/4" 
Wall Sleeve
FRONT
UNIT
FIG. 3
CAUTION:
We strongly recommend
the removal of the old wall sleeve and
the installation of a new LGE Wall Sleeve.
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of the
wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or product failure.
This is not covered under the terms of the LGE
warranty.
ITEM (inches)
Qty.
Plastic grille
26
3/4
x 16
1/2
1
Horizontal Insulation Strips 1
3/8
x
5/8
x 27
3/16
1
1
3/8
x 1
3/8
x 27
3/16
1
Around Insulation Strips
1
3/8
x
3/4
x 61
1/2
1
1
3/8
x 1
3/8
x 61
1/2
1
Support Block
1
3/4
x 1
3/8
x 4
5/16
2
Baffle
14 x 4
1/2
x
1/8
1
Shim
13 x 1 x
3/4
2
Trim Frame
2
Washer Screw
4
Nuts(Plastic)
4
Procedure
Brand
Depth(inches)
A
LGE
16-23/32
White-Westinghouse
Frigidaire Carrier
16, 17-1/2
(52F series)
or 22
B
General Electric
16-7/8
/Hotpoint
Whirlpool
17-1/8 or 23
Carrier (51S series)
18-5/8
Fedders/Emerson
16-3/4
or 19-3/4
C
Emerson/Fedders
15
Friedrich
16-3/4
Wall Sleeve Dimensions (inches)
Brand
Width
Height
Depth
White-Westinghouse
25-1/2
15-1/4
16, 17-1/2
Frigidaire
or 22
Carrier (52F series)
General Electric
26
15-5/8
16-7/8
/Hotpoint
Whirlpool
25-7/8
16-1/2
17-1/8
or 23
Fedders/Emerson
27
16-3/4
16-3/4
or 19-3/4
LGE
25-7/8 15-17/32 16-23/32
Emerson/Fedders
26-3/4
15-3/4
15
Carrier (51S Series)
25-3/4
16-7/8
18-5/8
Friedrich
27
16-3/4
16-3/4