Maintenance
1
Unplug power cord.
2
Wait until lamp is sufficiently cooled.
Wait for at least 1 hour.
3
Remove the lamp cover.
Loosen the screws on the  lamp cover and
remove the lamp cover.
4
Pull out the lamp.
Loosen the screws on the bottom of the lamp
assembly. Grasp the lamp handle and pull the
lamp assembly directly out of the projector.
5
Mount the new lamp.
Align the orientation, press down until the bottom is
reached, and lock in place using the lamp locking
screws.
6
Replace the lamp cover.
Align the cover, and press it in, then tighten the
screws loosened in step 
3
 until the lamp cover is
no longer loose.
Notes and Precautions
• Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the lamp may fail
to come on 
, and the lamp’s lifetime may be shortened.
• Always replace the lamp with a new one.
• The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or
scratch it. (Dirt, jolts, scratches and the like could break the lamp.)
■ Lamp Hours Reset
1
Select “Factory Reset” option in the Advanced menu.
2
Press control panel’s “+” Button 3 times and “–” button 3
times.
3
Lamp Hours will be automatically reset.