Chapter 6  Updating Drive Firmware
Updating the Drive Firmware from Tape
ATL M-Series User’s Guide
91
Updating the Drive Firmware from Tape
6
To update the drive firmware from tape:
1
Insert the drive firmware cartridge into the library and move it to the 
desired storage element (see 
2
Access the Service Drive screen (see 
).
3
Press 
Update
.
The GUI displays the 
Select Firmware Cartridge
 screen (see 
). 
A flashing arrow indicates the currently selected source element.
Figure 58  Select 
Firmware Cartridge 
Screen
4
If the library is an M1500 in a multiple library stack or an M2500, 
press the 
Level
 button to select the level where the drive firmware 
cartridge is located.
5
Press the 
Up
 and 
Down
 buttons to select the source element that 
contains the drive firmware cartridge.
6
When the flashing arrow is next to the source element that contains 
the drive firmware cartridge, press 
Select
.
The GUI displays the 
Select Tape Drive
 screen (see 
flashing arrow indicates the currently selected drive.