Quantum mc350 User Guide

Page of 166
Chapter 6  Fibre Channel Management
Bridge Administration
90
MC350 Prism Management Card User’s Guide
Enabling 
ExtendedCopy
 allows data being transferred directly from hard 
disk drive to tape cartridges without involving application servers except 
to initiate transfers and to receive reports of data transfer results (also 
known as Serverless Backup).
PortFailover
 is a failsafe measure designed to provide continuous library 
operation in the event of a Fibre Channel port failure without the loss of 
any of the library’s SCSI devices or the need for operator/field service 
technician intervention.
If enabled, Fibre port 2 out of 0, 1, and 2 is used as a reserved port. In case 
of port failure between 0 and 1, port 2 is switched on and replaces the 
failed port.
PortFailover Test
6
PortFailover
 
Test
 allows you to test the PortFailover feature by simulating 
a Fibre port failure condition on either port 0 or port 1. The tests include 
simulating a Port Down, Loop Down, or ISP Error condition. 
After simulating the condition, use the Bridge Status page to check the 
Fibre port status. These tests only work if PortFailover is enabled. You 
may recover the failed port by issuing the Recover test to the selected 
Fibre port.
Reboot Bridge
6
This option allows you to reboot individual bridges in your Fibre 
Channel configuration. Select the appropriate bridge and click 
OK
 to 
reboot the bridge selected from the pull-down list.
Note:
To receive an ALERT E-mail notification when a PortFailover 
event occurs, set the monitoring interval to a non-zero value 
Note:
The bridge takes approximately 30 seconds to reboot.