Champion eucc series User Guide

Page of 241
208
Motors
Low voltage:
115 VAC
208-240 VAC,50/ 60HZ, 1 and 3 PH
High voltage:
480 VAC, 50/60HZ, 3 PH
High voltage:
575 VAC, 50/60HZ, 3 PH
(Special order only -  Must have factory approval)
 120VAC, 50/60HZ, 1 PH
Horsepower:
Prewash pump:
  1, 2 or 3 HP
Wash pump:
  3 HP
Rinse pump:
  3 HP      
EconoRinse pump:
1/5 HP, 
(115 VAC)
Conveyor drive:
1/2 HP
Motor Wiring:
1.
Refer to the wiring diagram at right.
2.
208VAC/240VAC/3PH motors are connected per
the low voltage diagram.                         
3.
480VAC/575/3PH motors are connected per
the high voltage diagram.
4.
The 115 VAC econo-rinse pump motor has a
flexible power cord, (WHT, BLK, GRN wires).
Troubleshooting:
Motor will not run:
1.
Check incoming 3-phase power at the
main terminal block in the control cabinet.
2.
Check for tripped motor overload in control cabinet.
Motor runs hot and trips motor overload:
1.
Check for proper voltage between L1-L2, L2-L3, L1-L3.
2.
 Check FLA on motor leads L1, L2, L3 using amp tester.
(Motor full load amp ratings, (FLA), are stamped on motor nameplates).
Motor runs hot and trips motor starter overload:
1.
Check for proper voltage between L1-L2, L2-L3, L1-L3.
2.
Check FLA on motor leads L1, L2, L3 using amp tester.  (Motor full load amp (FLA)
ratings are stamped on motor nameplate).
Basic Service ________________
 
Electrical Service
Basic Service • Electrical