Champion model 66 pw Specification Guide
Volume crated:
152 cu. ft.
Shipping weight crated:
800 lbs.
Dimensions shown in inches
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary,
safety codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-1010
standard or equivalent) to be supplied
(by others) in common water supply line at service
connection.
Plumbing Notes:
Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves (PRVs) may
be needed. (Water PRV is standard on machines with
booster.) The PRVs can either be purchased from
Champion or obtained locally.
Venting Notes:
Fabricated duct size:
3-7/8” x 15-7/8” (Outside dimensions)
Machine only
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
103
125
125
240/60/1
90
110
110
208/60/3
58
70
70
240/60/3
50
60
60
480/60/3
25
35
35
575/60/3
19
25
25
TABle A - MACHINe CoNNeCTIoN
Machine and steam built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
25
35
35
240/60/1
22
30
30
208/60/3
13
20
20
240/60/3
11
20
20
480/60/3
6
15
15
575/60/3
5
15
15
TABle B - BooSTeR CoNNeCTIoN
70°F/39°C Rise – 48kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
133
175
175
240/60/3
115
150
150
480/60/3
58
80
80
575/60/3
48
60
60
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
utilities
1 Electrical
A Machine connection (see Table A)
B Booster connection (see Table B)
2 Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/22°C rise booster)
3/4” NPT 120°F/49°C min. hot water
3/4” NPT 120°F/49°C min. hot water
connection. (60°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
Flow pressure 20-22 psi.
3 Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4 Steam
A 3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
B 3/4” NPT machine connection.
B 3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam
injector)
5 Condensate
(no back pressure)
1/2” NPT machine return to boiler
6 Vents
A Load end: 200 CFM @ 1/4” S.P.
B Unload end: 400 CFM @ 1/4” S.P.
B Unload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
44” Single Tank with 22” Prewash
High-Temperature
Rack Conveyor Dishwashing Machine
Model 66 PW
SPeCIFICATIoNS
Capacity
Racks per hr. (NSF rated)
208
Wash tank (US gal.)
21
Conveyor speed (ft/min.)
5.8
Motor Horsepower
Drive
1/6
Prewash
1
Wash 2
Water Consumption
US Gal. per hr. (max. use)
234
US Gal. per rack
1.12
Heating
Tank Heat, electric (kW)
15
Tank heat, steam
(lbs/hr. required at
15 PSI flow pressure)
75
Electric booster (built-in)
(kW supplied for 40°F rise)
27
Electric booster
(kW supplied for 70°F rise)
48
Steam booster (lbs./hr.
required for 40°F rise)
120
Steam booster (lbs./hr.
required for 70°F rise)
205
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM) 400
Standard 20” x 20”
rack complement
Peg
2
Flat
1
40°F/22°C Rise – 27kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
75
100
100
240/60/3
65
80
80
480/60/3
32
40
40
575/60/3
27
35
35