Roland GW-7 Installation Instruction

Page of 20
1PS
 
1
 
Copyright © 2005  ROLAND CORPORATION
 
All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
 
Roland GW-7 MIDI Implementation
 
Model: GW-7
Date: Nov.24, 2004
Version: 1.00
 
1. Receive data
 
 
Channel Voice Messages
 
 
Note off
 
Status
2nd byte
3rd byte
8nH
kkH
vvH
9nH
kkH
00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
kk = note number: 00H - 7FH (0 - 127)
vv = note off velocity: 00H - 7FH (0 - 127)
*
For Drum Parts, these messages are received when Rx.NOTE OFF = ON for each
Instrument.
*
The velocity values of Note Off messages are ignored.
 
 
Note on
 
Status
2nd byte
3rd byte
9nH
kkH
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
kk = note number: 00H - 7FH (0 - 127)
vv = note on velocity: 01H - 7FH (1 - 127)
*
Not received when Rx.NOTE MESSAGE = OFF. (Initial value is ON)
*
For Drum Parts, these messages are not received when Rx.NOTE ON = OFF for each
Instrument.
 
 
Control Change
 
*
When Rx.CONTROL CHANGE = OFF, all control change messages except for Channel
Mode messages will be ignored.
*
The value specified by a Control Change message will not be reset even by a Program
Change, etc.
 
 
Bank Select (Controller number 0, 32)
 
Status
2nd byte
3rd byte
BnH
00H
mmH
BnH
20H
llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384), Initial value = 00 00H
*
Not received when System: Prog TxRx = OFF. (Initial value is ON)
*
Not received when Rx.BANK SELECT = OFF.
*
Rx.BANK SELECT is set to OFF by GM1 System On, and Bank Select messages will be
ignored.
*
Rx.BANK SELECT is set to ON by GM2 System On.
*
Rx.BANK SELECT is set to ON by power-on reset or by receiving GS Reset.
*
When Rx.BANK SELECT LSB = OFF, Bank number LSB (llH) will be handled as 00H
regardless of the received value. However, when sending Bank Select messages, you
have to send both the MSB (mmH) and LSB (llH, the value should be 00H) together.
*
Bank Select processing will be suspended until a Program Change message is received.
*
The GS format “Variation number” is the value of the Bank Select MSB (Controller
number 0) expressed in decimal.
*
Some other GS devices do not recognize the Bank Select LSB (Controller number 32).
 
+—————+———————————+———————————+——————————————————————+
| BANK SELECT     | PROGRAM   | GROUP                |
| MSB | LSB       | NUMBER    |                      |
+—————+———————————+———————————+——————————————————————+
| 000 | 000 —     | 001 — 128 | Preset Tone/Drum Set |
|  :  |           |           |  :                   |
| 064 | 000       | 001 — 128 | User Tone/Drum Set   |
| 120 | 000       | 001 — 057 | GM2 Drum Set         |
| 121 | 000 —     | 001 — 128 | GM2 Tone             |
+—————+———————————+———————————+——————————————————————+
 
 
Modulation (Controller number 1)
 
Status
2nd byte
3rd byte
BnH
01H
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Modulation depth: 00H - 7FH (0 - 127)
*
Not received when System: Mod TxRx = OFF. (Initial value is ON)
*
Not received when Rx.MODULATION = OFF (Initial value is ON)
*
The resulting effect is determined by System Exclusive messages. With the initial
settings, this is Pitch Modulation Depth.
 
 
Portamento Time (Controller number 5)
 
Status
2nd byte
3rd byte
BnH
05H
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Portamento Time: 00H - 7FH (0 - 127), Initial value = 00H (0)
*
This adjusts the rate of pitch change when Portamento is ON or when using the
Portamento Control. A value of 0 results in the fastest change.
 
 
Data Entry (Controller number 6, 38)
 
Status
2nd byte
3rd byte
BnH
06H
mmH
BnH
26H
llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
 
 
Volume (Controller number 7)
 
Status
2nd byte
3rd byte
BnH
07H
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Volume: 00H - 7FH (0 - 127), Initial value = 64H (100)
*
Volume messages are used to adjust the volume balance of each Part.
*
Not received when Rx.VOLUME = OFF. (Initial value is ON)
 
 
Panpot (Controller number 10)
 
Status
2nd byte
3rd byte
BnH
0AH
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Panpot: 00H - 40H - 7FH (Left - Center - Right), Initial value = 40H (Center)
*
For Rhythm Parts, this is a relative adjustment of each Instrument’s pan setting.
*
Not received when Rx.PANPOT = OFF. (Initial value is ON)
 
 
Expression (Controller number 11)
 
Status
2nd byte
3rd byte
BnH
0BH
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Expression: 00H - 7FH (0 - 127), Initial value = 7FH (127)
*
This adjusts the volume of a Part. It can be used independently from Volume messages.
Expression messages are used for musical expression within a performance; e.g.,
expression pedal movements, crescendo and decrescendo.
*
Not received when Rx.EXPRESSION = OFF. (Initial value is ON)
 
 
Hold 1 (Controller number 64)
 
Status
2nd byte
3rd byte
BnH
40H
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Control value: 00H - 7FH (0 - 127)
*
Not received when Rx.HOLD1 = OFF. (Initial value is ON)
 
 
Portamento (Controller number 65)
 
Status
2nd byte
3rd byte
BnH
41H
vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Control value: 00H - 7FH (0 - 127)  0 - 63 = OFF, 64 - 127 = ON
*