Savin is760 Installation Instruction

Page of 100
Connecting to the Computer
21
2
Connecting to the Computer
This scanner can be connected to the computer with either a SCSI, USB, or
IEEE1394 interface. An optional board will be required to connect with IEEE1394.
Important
❒ Do not turn the power of the scanner ON before the software installation. If you
run the "Found New Hardware Wizard" beforehand, you will not be able to in-
stall the software correctly. When the "Found New Hardware Wizard" started
before the installation, click the [Cancel] button to discontinue the wizard. 
Connecting with SCSI Interface
Standard, you can connect the scanner to two computers at the same time. One
with the SCSI interface, and one with the USB 2.0 interface. Though, you cannot
use the scanner at the same time from two computers. Interfaces are switched
automatically when you change from one of the computer to the other.
When the IEEE1394 interface board of the option is installed, you can connect the
scanner to three computers at the same time. One with a SCSI interface, and two
with the optional IEEE1394 interface. Though, you cannot use the scanner at the
same time from three computers. Interfaces are switched automatically when
you use any one of the computers.
About the SCSI Interface
Connection of this scanner to the SCSI (Small Computer System Interface) is as follows:
• This scanner is compliant for SCSI-3. You can daisy chain with SCSI-1/2 com-
pliant devices as well. The SCSI connecter of this scanner is male 50pin half-
pitch pin type. Use the shielded SCSI-2/3 cable compliant with ANSI (Amer-
ican National Standard Institute). Confirm in advance that some combination
of the SCSI cable and SCSI board on the computer may cause an incorrect
scanner operation. 
• This scanner is compliant for SCAM (SCSI Configured Automatically). If you
use SCAM corresponding to SCSI board and driver for your computer, the
SCSI ID will be set automatically. 
• This scanner has a built-in terminator. Set the DIP switches properly when
you connect the scanner with the SCSI interface.
Important
❒ Using other cable than ANSI compliant SCSI-2/3 shielded cable, may possibly
bring about malfunction or electromagnetic wave interference above VCCI rules.
❒ Connect a SCSI cable shorter than 4.9feet (1.5m) for the SCSI-3 (Ultra-SCSI), and a
9.8feet (3m) cable for the SCSI-2, including the cable length inside your computer.
❒ Some combinations of the SCSI board of your PC and daisy-chained periph-
erals might cause an incorrect operation. Please contact and ask your service
representative about the recommended SCSI board.