Enterasys sth-22 User Manual

Page of 35
 
UTP Cable Categories
 
Page 2-4
 
Category 3
 
 consists of (usually) four Unshielded Twisted Pairs of 
24 AWG solid wire for data or voice communication. (IBM Type 3 is 
coincidentally the same as UTP Category 3.) It is typically used to wire 
cable runs within the walls of buildings. In some installations, pre-
existing UTP building wiring can be used for Token Ring cabling. 
 
Warning: 
 
At 16 Mb/s ring speeds, some Category 3 cable does not meet 
the performance requirements of a Token Ring network. This may 
impose lower limits on lobe cable distances and ring node counts. See 
Table 2-1.
 
Categories 4 and 5
 
 are higher quality versions of category 3. They use the 
same gauge of wire but demonstrate superior performance due to 
improvements in material quality and assembly (e.g. more twists per 
foot).
 
Warning: 
 
Because Near-End Crosstalk (NEXT) contributes the 
majority of its detrimental effects near the end of a lobe cable, the 
quality of jumper cables and patch cables is most critical. Seek the 
highest practical grade. The quality of connectors and terminators is 
also critical.
 
Warning: 
 
Telephone Battery and Ringing voltages used in UTP 
telephone circuits could present a shock hazard and can damage Token 
Ring equipment if connected to Token Ring cabling. 
 
DO NOT connect 
 
Table 2-1. UTP Cable Category Specifications
 
UTP
Cat.
Operating
Frequency
Electrical
Impedance
Signal
Attenuation
per 100m
NEXT
loss
(@ 
 
 
100m)
3
  4 MHz
 
 100
Ω
  
±
15%
   5.6 dB
 32 dB
16 MHz
 100
Ω
  
±
15%
 13.1 dB
  
 23 dB*
4
  4 MHz
 100
Ω
  
±
15%
   4.3 dB
 47 dB
16 MHz
 100
Ω
  
±
15%
   8.9 dB
 38 dB
5
  4 MHz
 100
Ω
  
±
15%
   4.3 dB
 63 dB
16 MHz
 100
Ω
  
±
15%
   8.2 dB
 44 dB
*below Token Ring performance requirement of 