Enterasys 6000 User Guide

Page of 420
8-14
FRX/FRM 3. 3 User G uide, Rev 04
Subscriber Parameters
1 The  software does not verify that  the specified  LP/port exists. Make sure the specified 
LPs  and ports are configured in  the database, and  that they actually  exist.
Subscriber Name
identifies the subscriber to the console operator.
Routing Algorithm
allows creation of a "hunt group" of ports (see example in Appendix B), for the 
purpose of routing per a pre-selected algorithm:
0
 = Round Robin – selects ports specified cyclicly in numerical order according 
to the list of Redirection Addresses. If the selected port is unreachable or con-
gested, the Call Request will be sent to the next port. (If the port becomes 
available again, it will be included in its assigned position.)
1
 = Alternate Route on Line Failure – selects the first port that is not in a failed 
state. If the selected port does not make a connection, the call will be cleared, even 
if other  ports are  available.
2
 = Alternate Route on Line Busy – selects the first port that has LCNs available 
(is not busy). If the port has failed, the next available port will be selected.
= Least LCN with Throughput – selects the line with the minumum loading, cal-
culated by weight  and number of  LCNs in use on  that  line. (Each line is assigned 
a weight proportional to its throughput within the routing path.)
If use of a  routing  algorithm  is not desired, simply accept the default,  and  specify  only 
one routing path.
Table 8-3    SVC Subscriber Parameters
Parameter
Valid Values
Default  Value
Subscriber Name
0–31 characters
none
Routi ng Al gori thm
0–3
0
System atic Redirection
Y/N
N
Redir ect on Busy
Y/N
N
Redir ect on O ut of Order
Y/N
N
Connection Priority
0–9
0
1st,2nd,etc. Path  Configured
Y/N
N
LP
FRX4000, FRM:
 0 
1
FRX6000: 
0–7 
1
0
Port
Physical port:
 
0–7 
1
Logical port: 
8-63
 
1
0
Redir ection Address 0,1,etc.
valid address
none