Configuring BSC Interactive Port Records
Once the necessary Node, Line Processor, and protocol parameters have been con-
figured, press
figured, press
[A]
at the Port Configuration Menu (or
[A], [C], [A]
from the Main Menu.
When prompted, enter:
●
LP number of the RLP containing the port:
0–7
for FRX6000,
0
only for
FRX4000 or FRM. (The default is
0
.) (LP numbers are described in Chapter 4.)
●
Port number (see port locations in Chapter 5):
0–7
. (The default is
0
.)
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See Table 9-1 on page 9-3.)
The following figure is an example of an existing port.
display for a new port will show default database values. (See Table 9-1 on page 9-3.)
The following figure is an example of an existing port.
Figure 9-1 BSC Interactive Port Record
[A],[C],[A]
from Main Menu
If
BSC Type
(item J) is
2-HPAD
, item K will be
Answer Non-Configured
.
Pressing
[L]
lists more parameters, and pressing
[M]
displays a screen similar to the fol-
lowing. (All BSC Interactive parameters are listed in Table 9-1.)
N ode Name=n odexyz
BS C Interactive Port Parameters (screen 1 of 2)
*
*
RLP: 0
Port: 5
Link State: Linku p
*
I/O:–V .35
D atabase
Sys tem Memory
A Port Type
BS C I nter
BSC I nter
B Ph ysical Port I nterface
V .35
V.35
C Blocked Port Flag
N
N
D Lin e Sp eed
9600 bps
9600 bps
E Retran smission Period (ms )
2000
2000
F Maximum Retransmiss ion s
5
5
G Maximum Bytes p er Frame
4105
4105
H Generate Clock
Y
Y
I
Rcv C lock (TT) from D TE
N
N
J
BSC Type
1–tp ad
1–tpad
K Activate Conn ection w /o poll
Y
Y
L Interactive Parameters - Screen 2
M Sub scriber I nformation - Screen 3
N On -Lin e Sys tem Memory C hanges
M Sub scriber I nformation - Screen 3
N On -Lin e Sys tem Memory C hanges
Y
Option: