Enterasys 6000 User Guide

Page of 420
Configuring Async Ports
10-9
Configuring Async Port Records
Once the necessary Node, Line Processor, and protocol parameters have been con-
figured, press 
[A]
 at  the Port Configuration Menu  (or 
[A], [C], [A] 
from the Main Menu. 
When prompted, enter:
LP number of the RLP containing the port: 
0–7
 for FRX6000, 
0
 only for 
FRX4000 or FRM. (The default is 
0
.) (LP numbers  are  described in Chapter  4.)
Port number (see port locations in Chapter 5): 
0–7
. (The default is 
0
.)
The display for an existing port will show the configured parameter values, while the 
display for a new port will show default database values. (See Table 10-3 on page 10-
10.
) The following figure is an example of an existing port.
 
Figure 10-2    Async PAD Port Screen
[A],[C],[A]
 from  Main Menu
If a  record does not  exist  for  the async  PAD profile  identified by 
Initial 
Profile Name
, the letter 
U
 will be displayed preceding the name in the 
Database
 column.
Pressing 
[J], [K], [M]
, or 
[N]
 will display more parameters, listed in Table 10-3. Pressing 
[L]
 will display the async PAD profile parameters (listed earlier in this chapter) that 
are resident in the FRX/FRM software.
Node Name=nod exyz
As ync PAD Port Parameters 
*
R LP: 0
Port: 0
Lin k S tate: Link up
*
I /O:–RS -232
Databas e
System Memory
A Port Type
Asyn c PAD
Asyn c PA D
B Phys ical Port  In terface
RS-232
RS-232
C Blocked Port Flag
N
N
D X .3 Lin e Speed
autobau d
autobau d
E I nitial Profile N ame
90
90
F Login Required
N
N
G Parity
0,n one
0,non e
H D CE C able  Attached
N
N
I
Mask  Link  Alarms
N
N
J
X .25  Parameter Options
K A utocall Options
L Brows e Profile
M Modem S ign al  Options
N D is con nect Op tion s
O On-Line S ystem Memory  Chan ges
Y
Option: