Enterasys 6000 User Guide

Page of 420
10-16
FRX/FRM 3. 3 User G uide, Rev 04
Subscriber Parameters
1 The  software does not verify that  the specified  LP/port exists. Make sure the specified 
LPs  and ports are configured in  the database, and  that they actually  exist.
Subscriber Name
identifies the subscriber  to the console  operator. The FRX/FRM software does not  use 
this information.
Routing Algorithm
allows creation of a "hunt group" of ports (see example in Appendix B), for the 
purpose of routing per a pre-selected algorithm:
0
 = Round Robin – selects ports specified cyclicly in numerical order according 
to the list of Redirection Addresses. If the selected port is unreachable or con-
gested, the Call Request will be sent to the next port. (If the port becomes 
available again, it will be included in its assigned position.)
= Alternate Route on Line Failure – selects the first port that is not in a failed 
state. If the selected port does not make a connection, the call will be cleared, even 
if other  ports are  available.
2
 = Alternate Route on Line Busy – selects the first port that has LCNs available 
(is not busy). If the port has failed, the next available port will be selected.
3
 = Least LCN with Throughput – selects the line with the minumum loading, cal-
culated by weight  and number of  LCNs in use on  that  line. (Each line is assigned 
a weight proportional to its throughput within the routing path.)
If use of a  routing  algorithm  is not desired, simply accept the default,  and  specify  only 
one routing path.
Table 10-4    SVC Subscriber Parameters
Parameter
Valid Values
Default  Value
Subscriber Name
0–31 characters
none
Routi ng Al gori thm
0–3
0
System atic Redirection
Y/N
N
Redir ect on Busy
Y/N
N
Redir ect on O ut of Order
Y/N
N
Connection Priority
0–9
0
1st,2nd,etc. Path  Configured
Y/N
N
LP
FRX4000, FRM:
 0 
1
FRX6000: 
0–7 
1
0
Port
Physical port:
 
0–7 
1
Logical port: 
8–63
 
1
0
Redir ection Address 0,1,etc.
valid address
none