Enterasys 6000 Reference Guide

Page of 238
226
Cabletron  Relay Access Products
802.5 Token Ring (RFC1748) MIB Statistics
dot5StatsIfIndex
SYNTAX:
INTEGER
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Identifies the 802.5 interface for  which this entry  contains 
management information. The value of this object for a 
particular interface has the same value as the 
ifIndex object
defined in [4,6], for the same interface.
::= { dot5StatsEntry.1 }
dot5StatsLineErrors
SYNTAX:
Counter
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:This counter is incremented when a frame or token is 
copied or repeated by a station, the E bit is zero in the 
frame or token and one of the following conditions exists: 
(1) there is a non-data bit (J or K bit) between the SD and 
the ED of the frame or token, or (2) there is an FCS error 
in the  frame.
::= { dot5StatsEntry.2 }
dot5StatsBurstErrors
SYNTAX:
Counter
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:This counter is incremented when a station detects the 
absence of transitions for five half-bit timers (burst-five 
error).
::= { dot5StatsEntry.3 }
dot5StatsACErrors
SYNTAX:
Counter
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:This counter  is  incremented when  a station receives  an 
AMP or SMP frame in which A is equal to C is equal to 0,