Koblenz pv-500 k User Guide

Page of 8
3/8 
September
 / 2006
 
 
 
   
I.- OPERATING SYSTEM 
 
The vacuum cleaner can work from 105 to 135 V. 
 
The current must be of  3 to 4 Amps.  
 
There should be no abnormal noise or vibration, the carbon brushes spark should be small and uniform, and the commutator 
must have dark brown strip and uniform. 
 
 
II.-REPLACEMENT PROCEDURES 
 
1.- TO REPLACE MOTOR (9) 
1.1.- Pull release tab outward, at the same time pull cover up. 
1.2.- Remove the four screws (10). 
1.3.- Remove the cover (6). 
1.4.- Disconnect the line cord. 
1.5.- Remove the motor assembly (9). 
1.6.- Replace the motor (9) reconnect and reassemble. 
 
NOTE: Do not attempt to the repair motor send for service. 
 
2.- TO REPLACE THE ON-OFF SWITCH (1) 
2.1.- Follow steps 1.1 and 1.3. 
2.2.- Disconnect the two leads from the switch (1). 
Remove the three screws (7) the screw (9) and remove the cover top (3) replace the on-off switch reconnect and reassemble. 
 
3.- TO REPLACE THE LINE CORD 
3.1.- Follow steps 1.1 and 1.3. 
3.2.- Remove and replace the new line cord and reassemble as initially placed
 
4.- TO REPLACE THE FLOAT (15) 
4.1.- Follow steps 1.1 
4.2.- Remove the cage (15). 
4.3.- Remove and replace the float (14)