Error Messages
If the auto setup procedure could not be completed due to speaker installation, the measuring environment, etc., an error message is 
displayed. If this happens, check the relevant items, be sure to take the necessary measures, then perform the auto setup procedure over 
again.
Error messages (examples)
Cause
Measures
No microphone or speaker
• Included setup microphone is not connected.
• Not all speakers could be detected.
• The front L speaker was not properly detected.
• Connect  the  included  setup  microphone  to  the 
SETUP 
MIC
 jack on the main unit.
• Check the speaker connections.
Ambient  noise  is  too  high 
or Level is too low
• Too  much  noise  in  the  room  for  accurate 
measurements to be made.
• Speaker  or  subwoofer  sound  is  too  low  for 
accurate measurements to be made.
• Either  turn  off  any  device  generating  noise  or  move  it 
away.
• Try again when the surroundings are quieter.
• Check the speaker installation and the direction in which 
the speakers are facing.
• Adjust the subwoofer’s volume.
None
• Displayed speaker could not be detected.
·  The front R speaker was not properly detected.
·  Only  one  channel  of  the  surround  (A)  and 
surround (B) speakers was detected.
·  Sound was output from the R channel when only 
one surround back speaker was connected.
·  The surround back or the surround (B) speaker 
was  detected,  but  the  surround  (A)  speaker 
was not detected.
·  When  the  subwoofer  configuration  is  set  at 
“2SP L/R”, “2SP MIX”, “3SP L/R/LFE” or “3SP 
MIX”, the subwoofer could not be detected.
• Check the connections of the displayed speaker.
Phase
• Displayed speaker connected with the polarities 
reversed.
• If the XLR pre-out terminal is used, the polarity is 
reversed.
• Check the polarities of the displayed speaker.
• Check  the  polarity  setting  for  the  XLR  output  of  the 
displayed pre-set channel.
• For some speakers, this error message may be displayed 
even if the speaker is properly connected. If you are sure 
that the wiring is correct, select “Skip”.
Room EQ
Select room EQ setting method.
[Selectable items] 
All
 
Assign
s
Option
Select settings for room EQ, mic, etc.
Direct Mode
Select room EQ use for DIRECT or PURE DIRECT mode.
[Selectable items] 
ON
 
OFF
Mic Select
Select the microphone type if not using supplied mic.
The microphone connected to V.AUX Lch is used.
[Selectable items] 
Mic
 
V.AUX L
NOTE
 Be sure to turn the power off before checking the speaker connections.
 Select “Retry” to make the measurements again.
Only  a  professionally  certified  installer  should  ever  connect  a 
professionally-calibrated microphone to the V.AUX L input on the front 
panel.
• Sometimes due to the electrical complexities of subwoofers and the interaction with the room, THX recommends setting the level and the 
distance of the subwoofer manually.
• Sometimes due to interaction with the room, you may notice irregular results when setting the level and/or distance of the main speakers. If 
this happens, THX recommends setting them manually.
• Please note that any THX main speakers should be set to Small (80 Hz). If you set up your speakers using Auto Setup, please make sure 
manually that any THX speakers are set to Small with 80 Hz crossover.
d
Parameter Check
Check auto setup measurement results.
This is displayed after the auto setup procedure is 
completed.
[Selectable items]
Spkr Config Check
 
Distance Check
 
Ch. Level Check
 
Crossover Check
 
EQ Check
 
Restore
The auto setup results can be reset to what was originally calculated 
by MultEQ XT when “Restore” is selected.