U-Line clrco2175b40 User Guide

Page of 28
CLR2160, CLRCO2175
7
• It must have a check valve in the discharge line to 
prevent waste water return to the pump.
• It must have an overflow protection control which will 
shut off power to the ice maker in the event of a pump 
failure.
• It must have an operating temperature range of 50°F 
to 110°F (10°C to 40°C).
IMPORTANT
IMPORTANT
In the event of a power outage, restricted drain or 
pump failure, the failure to use the U-Line P60 drain 
pump or a pump with the above listed 
specifications, could result in substantial water 
leakage and pooling with severe and costly water 
damage and related consequential damages and 
harm.
Figure 8
Figure 9
Figure 10
WARNING
To prevent accidental electrocution, make certain 
that the floor surfaces surrounding the unit are 
dry whenever power is removed from, or applied 
to, the unit.
Figure 11
To connect to drain:
1. Slide 2 hose clamps onto the drain connection on the 
rear of the appliance.
2. Insert the barbed fitting halfway into this connection.
3. On the other end of this barbed fitting attach the 5/8” 
braided tubing.
4. Slide a clamp on each side of the barbed fitting as 
shown (Figure 11).
5. Insulate the drain line, if necessary to prevent 
condensation. Go on to Final Water/Drain Connection
Page 8.
Cold 
Water 
Hot 
Water 
Waste 
Waste 
Shut-Off 
Valve 
Stand Pipe
P60 Pump Required
ULIN_0571a_A
Air Gap 
(Optional Hook-Up) 
Cold 
Water 
Hot 
Water 
Waste 
Shut-Off 
Valve 
Disposal Assembly
P60 Pump Required
ULIN_0572a_A
Waste 
Cold 
Water 
Shut-Off 
Valve 
Hot 
Water 
Air Gap 
(Optional Hook-Up) 
Y-Branch Tailpiece
P60 Pump Required
ULIN_0573a_A
Drain Fitting from
Back of Unit
Worm Clamps
Drain Line
5/8" x 5/8"
Barb Connector
ULIN_S_0166b2_A