 3.3  Determining Drive and Sled Designations
The Diamond Storage Array has been designed with 12 sleds, each holding two drives. The easiest way 
to configure an array is to use all the drives on all the sleds. The firmware uses a numbering system to 
determine which drives and sleds it is affecting. 
All sled slots should be filled contiguously, 
starting with the first slot next to the management 
card. 
When configuring a array with fewer than 12 
drive sleds, you must consider several factors: 
RAID level, number of physical drives/sleds and 
the end configuration you are trying to achieve. 
Review the information about each configuration 
to determine how each configuration would be 
affected by using fewer sleds.
Numbering conventions
The Diamond Storage Array with firmware 
version 3.1 and newer uses a unique numbering 
convention to orient its drives and sleds to the 
controlling firmware. Older versions do not use 
this convention. (refer to 
Updating Firmware 
on 
page 75 for information about updating the array 
firmware.)
Physical 
refers to the physical drives in the array, 
the hardware that actually exists in a physical 
sense.
Logical (or virtual)  
refers to what the host 
operating system recognizes as an entity. Two 
physical drives may be seen as one logical drive 
by the operating system.
Logical disks do not always map one-to-one with 
physical disks. 
In RAID configurations, for 
example, several physical disk drives (or portions 
of several physical drives) are grouped into a 
logical disk, call a RAID Group or a Logical Unit 
(LUN). Each RAID group is broken into logical 
blocks of 512 bytes each, numbered 0 through n 
(the Logical Block Number or LBN). A 100 GB 
LUN has approximately 200,000,000 logical 
blocks. 
A RAID group is also referred to as a Virtual 
Drive.
 A LUN is associated with a RAID group or 
Virtual Drive unless you are using partitions. If 
you have partitions, a LUN is associated with 
each partition. A RAID Group or Virtual Drive 
may then have multiple partitions or LUNs.
Physical numbering 
The Diamond RAID Storage Array contains 
•  Up to 24 physical disk drives 
•  Two drives mounted on 12 
physical drive sleds 
•  Sleds are numbered 1-12, 
starting at the top (floor units) 
or the left (rackmount units). 
•  Each sled is connected to its 
own internal ATA bus with 
two disk drives, numbered 1 
and 2. 
•  Two green LEDs, labeled 
Drive 1 and Drive 2, indicate 
activity for the two drives. 
They remain solidly lighted 
when there is no activity.
  1             2           3
    4
    5             6            7             8              9            10           11         12
Rack Mount Drive Sleds
Management Card
Disk 2
LUN 13
Disk 2
LUN 14
Disk 2
LUN 15
LUN 16
LUN 17
Disk 2
LUN 18
LUN 19
LUN 20
Disk 2
LUN 21
Disk 2
LUN 22
Disk 2
LUN 23
Disk 2
LUN 24
Disk 1
LUN 12
Disk 1
LUN 11
Disk 1
LUN 10
Disk 1
LUN 9
Disk 1
LUN 8
Disk 1
LUN 6
Disk 1
LUN 4
Disk 1
LUN 3
Disk 1
LUN 2
Disk 1
LUN 1
Disk 1
LUN 5
Disk 1
LUN 7
Disk 2
LUN 19
Disk 2
LUN 20
Disk 2
LUN 17
Disk 2
LUN 16
  
1  
    
  
    
 2
    
    
  3
    
4
    
5
  
    
    
  
6
    
     
  
7
   
  
    
   8
   
  
    
    
 9 
  
    
    
 10
   
  
    
  1
1  
   
  
  12
Fl
oor
 M
ode
l  D
riv
S
le
ds
Drive 2
LUN 13
Drive 2
LUN 14
Drive 2
LUN 15
LU
N
 17
Drive 2
LUN 18
L
UN 1
9
LU
N
 2
0
Drive 2
LUN 21
Drive 2
LUN 22
Drive 2
LUN 23
Drive 2
LUN 24
Drive 1
LUN 12
Drive 1
LUN 11
Drive 1
LUN 10
Drive 1
LUN 9
Drive 1
LUN 8
Drive 1
LUN 6
Drive 1
LUN 4
Drive 1
LUN 3
Drive 1
LUN 2
Drive 1
LUN 1
Drive 1
LUN 5
Drive 1
LUN 7
Drive 2
LUN 19
Drive 2
LUN 20
Drive 2
LUN 17
Drive 2
LUN 16
Management card
Drive 1
LUN 6
Drive 1
LUN 12