ATTO Technology diamond array s User Manual

Page of 105
83
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
alarm will turn off when the fault condition is 
cleared or the alarm can be disabled by issuing a 
PowerAudibleAlarm
 or 
AudibleAlarm 
command via 
CLI as described in 
41. Disabling the alarm for a specific error will 
not silence the alarm for other error conditions.
Specific situations and suggestions
For all problems, first check the pages of the 
ExpressNAV interface appropriate for the 
problem especially the Status and Storage 
Management
 or use the appropriate CLI 
commands
If a drive fails to respond
•  Determine which drive has failed by observing 
the amber fault LED on the drive sled or connect 
to the CLI and type driveinfo
 
for a list of all 
drives and their status. 
•  For specific information on a particular drive in 
CLI, type
 
driveinfo [sled number] [drive 
number]. Record all errors.
•  Determine if the drive is configured in JBOD or 
RAID Level 0. 
•  Follow the instructions in the appropriate 
chapters of this manual for removing, replacing 
and reconfiguring the drive (begin with 
•  You may copy drives by using Command Line 
interface commands. (Refer to 
If a power supply fails
•  Verify the power cord is correctly plugged and 
there is power at the power receptacle.
•  If there is power, the cord is secure and the 
blower and power supply LEDs are off, replace 
the blower unit (refer to 
). 
•  If there is power, the cord is secure and the 
power supply LED is off, but the blower LED is 
on, replace the power supply (refer to 
•  Command Overlap: The array contains special 
software to take advantage of the Command 
Overlap feature offered in some high 
performance disk drives. Because all 24 disk 
drives in a Diamond Array may be seeking at the 
same time under Command Overlap, only 
arrays with two operational power supplies and 
blower assemblies will support Command 
Overlap: the array will automatically disable the 
Command Overlap feature if a power supply 
fails and notify the system administrator through 
the audible alarm and CLI.
If you cannot read or write to the array 
•  You may have lost connection to the host via the 
Host Interface Card. The Host Interface Card 
LED on the back of the array should be lit green. 
The amber LED should go out and the green 
LED should light when the connection is 
complete.
•  Also check the host bus adapter (HBA) in the 
host machine for proper functioning and drivers.
•  Verify that the connector and both ends of the 
cable are completely seated.
•  Try connecting directly to the host, bypassing 
any hubs or switches.
To determine if the problem exists with the HIC
•  Swap the cable from one HIC to the other HIC. 
•  If the LED is now green, swap the cable back to 
the original HIC. If the LED is amber, the HIC is 
defective.
•  Swap the defective HIC (refer to 
If you can’t access the CLI via Ethernet
•  Verify there are three or fewer concurrent 
sessions using Telnet or FTP. You may be the 
fourth session or someone in another session 
has entered a command which requires a Save 
Configuration command.
•  Verify you are using a crossover cable for direct 
connection, or a network cable for a network 
connection.
•  Verify the array is set to 
IPDHCP enabled
 if you 
expect an IP address will be assigned by the 
network and DHCP is an option available on the 
network.
•  Verify the IP address is compatible with the host 
machine.
•  Verify the system is functioning and accessible 
via in-band inquires such as Disk Management.
•  Try setting your terminal emulator with a 
different baud rate, starting at 2400, then 9600, 
19200, 38400, 57600, and 115200.