Sony VPL-VW85 Manual

Page of 86
65
 
Oth
e
rs
The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any 
trouble with your projector.
Warning Indicators
Symptom
Cause and Remedy
LAMP/COVER flashes in 
red. (A repetition rate of 2 
flashes)
c Close the lamp cover securely, then tighten the screws securely. 
c Close the filter holder securely. (1 page 70)
LAMP/COVER flashes in 
red. (A repetition rate of 3 
flashes)
c The lamp has reached the end of its useful lifespan. Replace the 
lamp. (
c The lamp has reached a high temperature. Wait until the lamp 
cools, and then turn on the power again. 
ON/STANDBY flashes in 
red. (A repetition rate of 4 
flashes)
c The fan is broken. Consult with qualified Sony personnel.
ON/STANDBY flashes in 
red. (A repetition rate of 2 
flashes)
c The internal temperature is unusually high. Check to ensure that 
if nothing is blocking the ventilation holes or whether or not the 
projector is being used at high altitudes.
ON/STANDBY flashes in 
red. (A repetition rate of 6 
flashes)
c Press the 
?
/
1
 (ON/STANDBY) switch to turn on the projector. If 
the power is not turned on, disconnect the AC power cord, then 
confirm the ON/STANDBY lamp is turned off. After about 10 
seconds, reconnect the AC power cord and turn on the power 
again. If the indicators still light up, the electrical system has a 
problem. Consult with qualified Sony personnel.
ON/STANDBY indicator
LAMP/COVER indicator