Zhone 2000 User Manual

Page of 297
2000-A2-GB20-10
- 239 -
February 2004
Lines 5 and 6 are connected together
Lines 7 and 8 are connected together
Hotline test started
6. Press Escape to terminate the test. The IAD terminates the test and 
displays the POTS Diagnostics menu.
Performing a Ring Test 
The ring test verifies that POTS device attached may be ringed by the IAD.
To perform a ring test:
1. Type R on the POTS Diagnostics menu to select Ring Test.
2. The IAD displays this prompt:
Ring all lines? (YN or ESC):
Enter Y to proceed, or N or Escape to abort and return to the menu.
THe IAD displays this prompt:
Ring lines concurrently or sequentially? (CS or 
ESC):
Enter C (concurrent), S (sequential), or Escape.
Listen for the rings to occur, and press Escape to terminate the test. 
The IAD terminates the test and displays the menu.
Performing a Power Supply Test
The power supply test checks the IAD power supply, SLIC and CODEC.
To perform a power supply test:
1. Type S on the POTS Diagnostics menu to select Power Supply Test.
2. The IAD tests each POTS line and reports the status.
3. Continue with other tests, or press Escape twice to return to the Main 
menu.
Performing a Phone Detect Test
The Phone Detect test detects POTS devices on each of the voice ports.
To perform a Phone Detect test:
1. Type P on the POTS Diagnostics menu to select Phone Detect Test.
2. The IAD tests for the presence of a POTS device on each port, and 
reports the status.
3. Continue with other tests, or press Escape twice to return to the Main 
menu.
Performing a Ring Test
The ring test rings all voice port lines either simultaneously or individually, 
in sequence.
To perform a ring test:
1. Type R on the POTS Diagnostics menu to select Ring Test.
2. The IAD displays the following prompt:
Ring all lines? (YN or ESC): y
Type Y to test all lines. 
—or—
Type N to test a specific line. The IAD prompts you for the port number.