5.9.2 Delete 
Encapsulation 
To delete encapsulation, select a VCC entry and then click on the Delete Encap button. 
5.9.3  Add a VCC 
To add a VCC entry, complete the following steps. 
STEP 1: Click on the Add VCC button. The VCC screen appears. 
STEP 2: Enter values for the parameters (explained below). 
STEP 3: Click on the Apply button at the bottom of the page. 
VPI 
Virtual Path Identifier (VPI) that identifies this ATM 
connection. The valid range is 0 to 4095.  
VCI 
Virtual Channel Identifier (VCI) that identifies this ATM 
connection. The valid range is 0 to 65,535. 
Peak Cell rate 
(cells/sec) 
Defines the fastest rate a user can send cells to the 
network. It is expressed in cells per second. 
Average Cell rate 
(cells/sec) 
Defines the maximum sustainable average rate a user can 
send cells to the network. It is expressed in cells per 
second. This specifies the bandwidth utilization. This value 
must always be less than or equal to the Peak Cell Rate. 
Burst size (cells) 
Maximum number of cells the user can send at the peak 
rate in a burst, within a sustainable rate. 
CDVT (cells) 
Constrains the number of cells the user can send to the 
network at the maximum line rate. 
Type 
Select data or voice