Polaroid fla-1512b User Guide

Page of 19
 
TROUBLESHOOTING  
Before calling a technician, please check the following table to see if the below 
mentioned symptoms can be diagnosed and fixed. 
Symptoms Possible 
Reasons 
Correction 
No picture, no 
sound, and no 
indicator light 
on 
1.  The power cord is not plugged 
in 
2.  The power is off 
 
1.  Plug the power cord in 
2.  Turn on the power 
 
No picture, no 
sound, but the 
green light 
indicator 
Functions of ON/OFF TIME and 
SLEEP have been set 
 
Press
【      】to turn on the TV   
No picture, no 
sound, but the 
yellow light 
indicator 
1.PC is in VGA Mode without any 
PC signal input 
2.The signal cord is not connected 
correctly 
1.Press 
【    】or input the PC 
signal 
2.Connect the signal cord 
properly 
Picture and 
sound with 
abnormality 
1.Contrast, sharpness, and colour 
are set improperly   
2.Colour system is set improperly 
3.Sound system is set improperly 
1.Adjust the value of Contrast, 
sharpness, and colour   
2.Set the Colour System to the 
country broadcasting standard 
3.Set the Sound System to the 
country broadcasting standard 
Picture is 
spotted or with 
snow 
Signal source is low-grade or the 
signal is in a lower quality   
Use the qualified signal cord 
Blue 
background 
No Video signal or the signal cord is 
improperly/not connected   
Connect the signal cord properly 
Picture is 
unclear, or 
moves or have 
black stripes 
on horizontal 
position in PC 
mode 
Picture is not well adjusted   
Adjust automatically by selecting 
Auto Adjust or adjust Clock 
、 
Phase
、H Position and V Position 
manually after enter into the PC 
Setup menu to solve this problem 
PC Picture is 
not in the 
middle of the 
screen 
Picture is not well adjusted   
Adjust pictures automatically by 
resetting  H Position
、V Position、
Phase and Clock 
No sound 
No Audio signal or the signal cord is 
improperly/not connected 
1.Connect the audio signal cord 
properly 
2.Set the sound system properly 
The remote 
control does 
not work 
Batteries are improperly installed or 
exhausted  
1.Make sure the positive and the 
negative polarities are correct. 
2.Check if there is loose contact 
between the springs and the 
batteries. 
3.Replace the batteries 
16