INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here. 
Parts supplied:
Remove parts package from dryer drum. Check that all parts were 
included.
4 leveling legs
Parts needed:
Check local codes, check existing electrical supply and venting 
and see “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please reference the 
“Assistance or Service” section of the Dryer User Instructions.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes 
dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
minimum. The cord should be type SRD or SRDT and be at 
least 4 ft (1.22 m) long. The wires that connect to the dryer 
must end in ring terminals or spade terminals with upturned 
ends.
A UL listed strain relief.
Location Requirements 
You will need
A location that allows for proper exhaust installation. 
See “Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft (610 mm) of either side of the dryer. 
See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) 
of 200 lbs (90.7 kg). The combined weight of a companion 
appliance should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire 
dryer. (If slope is greater than 1" [25 mm], install Extended 
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble 
properly and models with automatic sensor cycles may not 
operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be 
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that 
opens to 1" (25 mm) or 
hex-head socket wrench 
(for adjusting dryer feet)
Wire stripper (for U.S. 
only, direct wire 
installations)
Tin snips (new vent 
installations)
Level
Vent clamps
Caulking gun and 
compound (for installing 
new exhaust vent)
Tape measure