Amana ned5500tq Installation Instruction

Page of 36
2
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here. 
Parts supplied:
Remove parts package from dryer drum. Check that all parts were 
included.
4 leveling legs
Parts needed:
Check local codes, check existing electrical supply and venting 
and see “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please reference the 
“Assistance or Service” section of the Dryer User Instructions.
Location Requirements 
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft (61 cm) of either side of the dryer. See 
“Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 
200 lbs (90.7 kg). The combined weight of a companion 
appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. (If slope is greater than 1" [2.5 cm], install Extended 
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble 
properly and models with automatic sensor cycles may not 
operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be 
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes or 
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open 
fully. 
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that 
opens to 1" (2.54 cm) or 
hex-head socket wrench 
(for adjusting dryer feet)
Wire stripper (for U.S. 
only, direct wire 
installations)
Tin snips (new vent 
installations)
Level
Vent clamps
Caulking gun and 
compound (for installing 
new exhaust vent)
Tape measure
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as 
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor 
for a garage installation.
Failure to do so can result in death, explosion, or fire.
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
 
   
 
   
   
 
   
43
³⁄₈
"
(110 cm)
*26"
(66 cm)
29"
(73.66 cm)
A
15¼"
(38.74 cm) 43
³⁄₈
"
(110 cm)
*27¾"
(70.5cm)
29"
(73.66 cm)
B
22 ¾"
(57.8 cm)
43
³⁄₈
"
(110 cm)
13 ¾"
(34.9 cm)
*27 ¾"
(70.5 cm)
29"
(73.66 cm)
D
43
³⁄₈
"
(110 cm)
*27 ¾"
(70.5 cm)
29"
(73.66 cm)
C