1 Welcome
Congratulations on your purchase of a Crown
®
 
CH or CL Series commercial power amplifier. 
The CH and CL Series is a complete family of 
amplifiers with a wide range of power output 
capabilities and output configurations. 
CH Series amplifiers can directly drive “con-
stant voltage” lines, so you can avoid the 
expense of adding step-up transformers for 
distributed loudspeaker systems. CL Series 
amplifiers offer low-impedance compatibility 
for applications where high-power, low-imped-
ance loads are the primary requirement. 
All CH and CL Series amplifiers feature 
Crown’s exclusive SST (System Solutions 
Topologies) expansion system. The SST expan-
sion system makes it easy to tailor your ampli-
fier to a specific application or to add future 
technology as it develops (see Section 4.3.2 for 
descriptions of available SSTs).
Modern power amplifiers are sophisticated 
pieces of engineering capable of producing 
extremely high power levels. They must be 
treated with respect and correctly installed if 
they are to provide the many years of reliable 
service for which they were designed.
In addition, CH and CL Series amplifiers 
include a number of features which require 
some explanation before they can be used to 
their maximum advantage.
Please take the time to study this manual so 
that you can obtain the best possible service 
from your amplifier. 
1.1 Features
The CH and CL Series amplifiers are 
designed specially for fixed installation, 
and include the following features:
CH Series provides for both low imped-
ance and high impedance loads, with the 
choice of 4/8 ohm or 70V operation for 
each channel. The output mode of each 
channel can be set independently, allowing 
unique or mismatched loads to be driven 
by each channel.
CH Series includes a 70-Hz high-pass fil-
ter for each channel (when used in 70V 
mode) providing necessary low-frequency 
roll-off to eliminate saturation of constant 
voltage step-down transformers typically 
used in 70V distributed systems.
CL Series includes high power 2-ohm 
operation, for jobs where low impedance is 
the only requirement.
A red five-way Fault LED for each channel 
blinks during amplifier power-up, and 
upon the following fault conditions: exces-
sive heatsink temperature; transformer 
thermal protection; short at amplifier out-
put; output stage non-operational.
An RJ11 connector allows external circuits 
to monitor the status of the Fault circuit.
Detented level controls are located on the 
back panel for security, and allow for accu-
rate level settings.
Barrier strip output connectors allow for 
quick easy connection regardless of the 
load, and accept up to 10 AWG crimp-on 
terminal forks.
SST modules provide flexible input 
options, such as onboard crossover con-
figurations.
Stereo/Bridge switch allows conversion 
from Stereo mode to Bridge mode for 
higher-powered single-channel operation.
Advanced protection circuitry guards 
against: shorted outputs, open circuits, 
DC, mismatched loads, general overheat-
ing, high frequency overloads and internal 
faults.
Three Year, No-Fault, Fully-Transferable 
Warranty completely protects your invest-
ment and guarantees its specifications.
1.2 How to Use This Manual
This manual provides you with the necessary 
information to safely and correctly setup and 
operate your amplifier. It does not cover every 
aspect of installation, setup or operation that 
might occur under every condition. For addi-
tional information, please consult Crown’s 
Amplifier Application Guide (available online at 
www.crownaudio.com), Crown Technical Sup-
port, your system installer or retailer.
We strongly recommend you read all instruc-
tions, warnings and cautions contained in this 
manual. Also, for your protection, please send 
in your warranty registration card today. And 
save your bill of sale — it’s your official proof 
of purchase.
Output Power
Output Power at 1 kHz at rated THD; Stereo mode, per channel with both channels driven.
                                  STEREO MODE                                                            BRIDGE MODE
 
2 Ohms 
4 Ohms 
8 Ohms 
70V 
 
4 Ohms  8 Ohms 
140V 
CH1  450W 275W 300W   
  900W 600W 
CH2  660W 
400W 
600W 
                             1320W       1200W 
CH4 
1400W 
1200W 600W 1200W   
  2400W 2400W
CL1  560W 450W 275W 
 
  1100W 
900W
CL2  975W 660W 400W 
 
  1950W 
1320W
CL4 1800W* 
1200W 600W 
 
  3600W* 
2400W
≥ 200VAC Line Voltage
2800W
Output Power
Output Power at 1 kHz at rated THD; Stereo mode, per channel with both channels driven.
STEREO MODE