Minimum Guaranteed Power 
Xs500
Xs700
Xs900
Xs1200
120 VAC, 60 Hz Units, per channel, both channels driven
1 kHz with 0.15% THD
Dual, 2 ohms (per ch.)
750W*
900W*
1200W*
1600W*
Dual, 4 ohms (per ch.)
500W
750W
900W
1100W
Dual, 8 ohms (per ch.)
400W
450W
600W
650W
Bridge mono, 4 ohms
1600W*
1900W*
2500W*
3000W*
Bridge mono, 8 ohms
1450W
1645W
2100W
2300W
Performance
Xs500
Xs700
Xs900
Xs1200
Sensitivity (volts RMS) for full rated power at 4 ohms
1.4V
1.4V
1.4V
1.4V
Frequency Response (at 1 watt, 22Hz - 22 kHz)
± 1 dB
± 1 dB
± 1 dB
± 1 dB
Phase Response (at 1 watt, 20Hz to 20 kHz)
+5°, –18°
+5°, –18°
+5°, –18°
+5°, –18°
Signal to Noise Ratio below rated power (typical)
   A-weighted
   22 Hz to 22 kHz filter
> 102 dB
> 97 dB
> 103 dB
> 98 dB
> 108 dB
> 106 dB
> 109 dB
> 107dB
Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20 
Hz to 20 kHz
< 0.5%
< 0.5%
< 0.5%
< 0.5%
Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,
from full rated output to –30 dB
from full rated output to –40 dB
< 0.5%
< 1.0%
< 0.5%
< 1.0%
< 0.5%
< 1.0%
< 0.5%
< 1.0%
   
6 Specifications
OUTPUT ASSIGNMENT
PIN
CH
PIN
CH
1+
2
1+
1
1–
2
1–
1
2+
NC
2+
2
2–
NC
2–
2
CH 2
CH 1