7.0  Set-Up and Assembly 
7.1  Floor Diagram 
 
Figure 2 
7.2  Unpacking and cleanup 
Inspect contents of shipping container for 
shipping damage. Report any damage to your 
distributor. 
Remove all contents from carton, and compare 
to the contents list in this manual. Report any 
part shortages to your distributor.  
Do not discard carton or packing material until 
belt grinder is assembled and running 
satisfactorily. 
Exposed metal areas may have a rust protectant 
applied. Remove this with a soft rag and WD-
40
®
 or kerosene. (Do not use gasoline, paint 
thinner, acetone, etc., as these will damage 
painted surfaces.) 
Contents of shipping container 
1 Belt 
Grinder 
Instructions and Parts Manual (not shown) 
Warranty Card (not shown) 
7.3  Electrical Connections 
  Electrical connections must 
be made by a qualified electrician in 
compliance with all relevant codes. This 
machine must be properly grounded to help 
prevent electrical shock and possible fatal 
injury.
 
The belt grinder is equipped with a single phase 
230 volt only motor; or a 3-phase 230/460V 
(prewired 230V) motor. A plug is not included. 
You may either install a UL/CSA listed plug 
suitable for the specified voltage, or hard-wire 
the machine directly to a service panel.  
If the machine is to be hard-wired to a panel, 
make sure a disconnect is available for the 
operator. During hard-wiring of the machine, 
make sure the fuses have been removed or the 
breakers have been tripped in the circuit to 
which the machine will be connected. Place a 
warning placard on the fuse holder or circuit 
breaker to prevent it being turned on while the 
machine is being wired. 
Grounding Instructions 
This machine must be grounded. In the event of 
a malfunction or breakdown, grounding provides 
a path of least resistance for electric current to 
reduce the risk of electric shock.  
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor.  If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded. Repair or 
replace a damaged or worn cord immediately. 
Make sure the voltage of your power supply 
matches the specifications on the motor plate of 
the belt grinder. 
It is recommended that the single-phase belt 
grinder be connected to a dedicated, minimum 
50 amp circuit with a 50 amp circuit breaker or 
time-delay fuse; the three phase belt grinder (at 
230 volt operation) be connected to a dedicated 
minimum  30 amp circuit with a 30 amp circuit 
breaker or time delay fuse; and the three phase 
belt grinder (at 460 volt operation) be connected 
to a dedicated, minimum  15 amp circuit with 15 
amp circuit breaker or time delay fuse. Local 
codes take precedence over recom-
mendations.
 
7.4  Voltage Conversion (3PH only) 
To convert the 3-phase belt grinder from 230 to 
460 volt operation: 
1.  Switch the incoming power leads according 
to the diagram inside the motor junction box. 
Similar diagrams are found in Section 13 of 
this manual. (In case of discrepancy, the 
diagrams in the motor junction box will take 
precedence.) 
2.  Make sure connections to transformer are 
suitable for the new voltage. 
3.  If a plug is being used, install a UL/CSA 
listed plug suitable for 460 volt operation.