7.  Check gearbox fluid level in sight gauge. If 
required, add lubricant to bring level halfway 
up the sight gauge. (Two containers of Shell 
Spirax 90 HD gear oil are packed with the saw. 
The containers have sufficient amount of 
lubricant to fill the gearbox.) 
8.  Check blade tension and support mechanism 
adjustment (refer to Changing Saw Blades). 
9.  Plug the motor cable into the switch box on the 
saw frame. For 3-phase motors, follow the 
instructions in the Electrical section to 
complete the electrical hookup. 
NOTE:  Observe all electrical codes. Local codes 
or difficult environmental conditions may demand 
special electrical hook-ups. Always use a licensed 
electrician for any special electrical hook-up. 
Setting-up Saw 
The saw should be bolted securely to the shop 
floor  to  make  sure  the  saw  is  stable  when  sawing 
long, heavy or unwieldy work pieces.  Always use 
extra support for long or heavy stock. There are 
lugs in the bottom of the saw base for use in 
bolting down of the saw.  After positioning the saw, 
open the door in the base and mark the positions 
ofthe four lug holes.  Move the saw to expose the 
marks. Prepare for attachment as required by the 
attachment method being used. Install the 
applicable fasteners. Install shims as required to 
level the saw. Tighten the fasteners to secure the 
saw to the floor.  
Electrical  
Models J-8201 and J-8201VS are delivered with a 
115volt single phase motor.  Models J-8203 and J-
8203VS are delivered with a 220/440 volt, 3-phase 
motor. 
When the saw is a 115 volt model, it is supplied 
with a standard 115 volt plug and power cord which 
can be plugged into any suitable branch circuit. 
When the saw is equipped with a 3-phase motor 
there will be no plug on the 4-wire cable to the saw 
switchbox. Instead, follow these instructions to 
connect the 3-phase motor to the power source: 
Connecting to 3-phase power 
1.  Disconnect and lock out the branch circuit to 
the saw before attempting electrical 
connections. 
2.  Connect the green or green-with-white-trace 
wire to the branch circuit ground wire. 
3.  Connect the remaining three wires to the 
power wires in the 3-phase branch circuit. 
4.  Reestablish power in the electrical branch. 
5.  Turn on power to the saw motor using the 
switch. 
6.  Observe the direction of the blade. It should be 
going DOWNWARD, into the slot on the table.  
If it is not going downward, the power wires 
are hooked-up incorrectly. 
7.  To correct hook-up, disconnect and lock out 
power to the branch, again. Reverse any two 
of the power wires on the hook-up to the saw 
cable. 
8.  Reestablish power in the branch and turn the 
saw on again. The blade should now be going 
downward into the table slot. 
Note: local electrical codes or other codes may re-
quire direct connection to a covered, protected 
junction box, or other electrical hook-up method.  
Especially under difficult industrial conditions, 
specialized electrical connections may be 
necessary. For special electrical hook-ups, a 
licensed electrician should be used to connect the 
saw to power.  
CAUTION: KNOW AND OBSERVE ALL LOCAL 
AND OTHER APPROPRIATE ELECTRICAL 
CODES WHEN ATTACHING THIS BAND SAW 
TO YOUR POWER SUPPLY. 
 
Figure 4: Wiring Diagrams