ROUTINE MAINTENANCE   5 - 15
5
Put the new fusing unit into the printer. Be sure to insert the fusing unit completely into the printer.
Figure 5-17
6
Secure the fusing unit with the two lock levers that are on both sides of the fusing unit.
Figure 5-18
7
Move the fusing unit pressure release levers to the Set position.
Figure 5-19
8
Close the back cover.
9
Turn the printer power switch back on.
10
Press any of the 
Menu
 buttons (
+
,
 –
,
 Set
 or 
Back
) to take the printer off line. 
11
Press + or  until RESET MENU appears.
12
Press 
Set
 to proceed to the next menu level, and then press 
+
 or 
 until PARTS LIFE appears.
13
Press 
Set
, and then press 
+
 until FUSER UNIT appears.
14
Press 
Set
. The printer is now in the READY state.
Please be careful when replacing the fusing unit. Do not put pressure on the fusing unit; it should 
go in easily. If it does not, make sure the fusing unit connector is free to move. 